Products Technical Specifications (18,23,26 and 38 GHz)

Technical Specifications (18,23,26 and 38 GHz)

Pinnacle Digital Microwave Radios
Operating at 13, 15, 18, 23, 26 & 38 GHz with Capacities of 155 Mbit/s OC-3/STM1 and Ethernet 100BaseT

Pinnacle radios are specifically designed for high capacity synchronous and IP based applications including first and last mile network access, Sonet/SDH ring closure, and cellular base station backhaul. Pinnacle radios are meeting the growing demand for more bandwidth while maintaining high spectrum efficiency.

Pinnacle
Pinnacle’s versatile design allows low-cost transmission of high-capacity data through narrow or congested spectrum. This spectral efficiency is complimented by a physical architecture that promotes rapid and cost-effective installations. Using multiple plug-in modules, the indoor unit (IDU) provides various customer signal interface(s) as well as access to the SNMP and local management ports for on-site commissioning and maintenance. The outdoor unit (ODU) consists of an RF unit directly integrated with a low-profile antenna - all connected to the IDU through a single coaxial cable. For critical paths, Pinnacle can also be configured for redundant hardware protection (1+1) using either a single or dual antenna design.

Versatile

  • Plug-In data interface modules are field interchangeable and allow simple access to all standard interfaces           
  • Transport for ATM and SONET/SDH based systems           
  • 100 BaseT Interface is ideal for LAN, WAN & ISP           
  • Last-mile spur access           
  • Cell based network back haul for GSM, PCS, Cellular, 3G

Easy To Install & Operate

  • Typical install time of less than 3 hours           
  • Integrated ODU/Antenna assembly           
  • Up to 1000 feet separation between ODU/IDU           
  • Simple graphical interface for initial set-up and maintenance           
  • Internal loopbacks, separate TX/RX switching, remote software downloads           
  • SNMP management interface

Reliable

  • Highly integrated MMIC, DSP, and flash technologies           
  • Extended MTBF           
  • Increased availability using redundant configuration           
  • Complete Digital Design           
  • Designed and Manufactured using ISO 9001 Standards

Technical Advantages

  • 128 QAM modulation allows narrow 28 MHz operation           
  • Offers a high gain option for wideband channels           
  • Advanced forward error correction (FEC)           
  • Automatic Transmit Power Control (ATPC)           
  • Dual FLASH memory for software backup           
  • Common IDU reduces sparing and operating costs

Outdoor_Unit BackPanel

OUTDOOR UNIT 13, 15, 18, 23, 26 & 38 GHz

Integrated RF / Antenna assembly
Eliminates waveguide loss, allows polarization selection and simplifies RF replacement without affecting antenna alignment.

OUTDOOR UNIT (ODU) Features

RF Unit
Antenna
AGC Monitor Port.
RF Unit Latch 
Antenna Alignment Adjustments (Vertical and Horizontal)

INDOOR UNIT 155 Mbit/s, STM-1/OC-3
Rack Mountable Either Direction

Indoor_Unit BackPanel

INDOOR UNIT Back Panel

INDOOR UNIT (IDU) Features
Alarm/Status LEDs
Plug-In Line Interface Module
Accessory Port (Async Service Channel & HSB interconnection)
Modem Port for Remote Dial-in Access
Alarm Relays
Network Management (10 Base-T SNMP)
+24 or -48 VDC
IDU to ODU Connection Single Coax Cable (RG-8 up to 300m)
Local Control Craft Terminal or PC Interface (RS 232)

Technical Specifications¹²

System Parameters

Frequency Bands: 13-38 GHz

Frequency Stability: ±2 ppm

Residual BER: <10 -13

Transmitter Type: Digital modulator, up-converter

Power Control (ATPC): 0 to 25 dB

Receiver Type: Down converter, coherent demodulation

Standards Compliance

System: FCC Part 101, ETSI EN 301 751

Antenna: FCC Part 101 Category A or ETSI high-performance, BABT 211 ZV Class 2

EMC: FCC Part 15 Class B, ETSI ETS 300 385, EN 301 489

Payload/Interface: SONET applicable standards, ITU-T G.703, G.707, G.783, G.823, G.826, G.957, G.958

Payload

Capacity: 155.52 Mbit/s

Type: Clear channel or SONET/SDH regenerator section

Electrical Interface: CMI, BNC connectors

Optical Interface: Single or multi-mode Intra-office, short or long haul
SC, ST or FC connectors

Service Channels: 19.2 Kbits asynchronous; RS-232
2 x 64 Kbits synchronous; G.703

Wayside Channel: T1 or E1; G.703

Ethernet User Interface: 100BaseT
100BaseT + 2T1/2E1100BaseT + 2T1/2E1 + DS3/E3

Frequency Dependent Parameters

General 

13 GHz

15 GHz

18 GHz

23 GHz

26 GHz

38 GHz

Frequency Range 

12.75- 13.25 GHz

14.4- 15.35 GHz

17.7-19.7 GHz

21.2-23.6 GHz

24.5-26.5 GHz

37.0-40.0 GHz

T/R Spacing 

266 MHz

420, 490, 728 MHz

1010, 1560 MHz

1008,1200, 1232 MHz

1008 MHz

700, 1260 MHz

ETSI Specifications 

EN 300 234 Class 5B

EN 300 234 Class 5B

EN 300 430 Class 5A

EN 300 198 Class 5A

EN 300 431 Class 5A

EN 300 197 Class 5A

Standard Bandwidth

Output Power  

-

-

18.0 dBm

17.0 dBm

17.0 dBm

17.0 dBm

Channel Bandwidth

-

-

40 or 55 MHz

50 or 56 MHz

56 MHz

50 or 56 MHz

Modulation 

-

-

32 or 16 QAM

16 QAM

16 QAM

16 QAM

Threshold @ 10 -6 BER   

-

-

-71 or -73 dBm

-71 dBm

-71 dBm

-70 dBm

FCC Emission Designator     

-

-

40M0F7W

50M0F7W

-

50M0F7W

Narrow Bandwidth

Output Power 

18.0 dBm

19.0 dBm

15.5 dBm

14.5 dBm

14.5 dBm

14.5 dBm

Channel Bandwidth 

28 MHz

28 MHz

27.5 MHz

28 MHz

28 MHz

28 MHz

Modulation 

128 QAM

128 QAM

128 QAM

128 or 256 QAM

128 QAM

128 or 256 QAM

Threshold @ 10 -6 BER 

-69 dBm

-69 dBm

-69 dBm

-68 dBm

-68 dBm

-67 dBm

FCC Emission Designator    

-

-

-

25M0F7W

-

25M0F7W

General Parameters

Antenna

Type: Parabolic reflector; integrated or external

Diameter: 1' (30 cm), 1.5' (45 cm), 2' (60 cm), 3' (90 cm), 4' (120 cm), 6' (180 cm)

Wind Loading: Operational: 100 mph (160 km/h), Survival: 125 mph (220 km/h)

Polarization: Linear (vertical or horizontal)

Adjustment Angle: ±35° elevation, ±15° azimuth

Power

Standard Input: -36 VDC to -60 VDC

Optional Input²: 24 VDC ± 20%

Power Consumption: 115 watts (non-protected); 240 watts (protected)

Environmental

Temperature:

Operational Range: ODU: -50°C to +55°C

Full Performance: ODU: -33°C to +55°C / IDU: -5°C to +45°C

Relative Humidity: ODU: 100%, IDU: up to 95% non-condensing

Altitude: 15,000 feet (4,500 m)

Mechanical

IDU Dimensions: 1 RU (4 cm) x 19" (44.5 cm) x 12" (30.5 cm) (h x w x d)

IDU Weight: 4.7 lbs. (2.14 kg)

ODU Dimensions: 38 GHz: 13" x 13" x 12" (33 x 33 x 30.5 cm) (h x w x d) 

13/15/18/23/26 GHz: 11.8" x 9" x 6.3" (30 x 23 x 16 cm) (h x w x d)

ODU Weight: 15.4 lbs. (7 kg) includes RF assembly only

IDU to ODU Connection: 1 coaxial cable up to 1000' (300 m), Belden 9913 (RG-8) or equivalent, 2 'N' type male connectors

Network Management

Type: Integral SNMP agent, Craft Terminal Interface (CTI), GUI interface

Physical Interface: PPP over RS-232 modem port (up to 56 Kbit/s), 10 BaseT Ethernet port, VT100 craft terminal port (9.6 Kbit/s)

User Interface: SNMP, CTI via Telnet, CTI via direct serial
interface, GUI interface

Security: 3-level password protection, Challenge Protocol (CHAP) security

Remote Software Updates: Flash download via TFTP over Ethernet or dial-up PPP

NMS Compatibility³: OpenViewä, NetViewä or any SNMP-based NMS

NM IP Rating: IP addresses for radios and third-party equipment accessible over multiple cascaded links

Protected Branching Loss

 

Primary

Standby

Transmit

1.5 dB

6.5 dB

Receive

1.5 dB

6.5 dB

Footnotes
1) All specifications are subject to change without notice.
2) Non-protected specifications.
3) OpenView and NetView are registered trademarks of Hewlett Packard Corporation and IBM Corporation.