Our Coordinates: Lat 42.75 N, Long 71.85 W |
|
Products Technical Specifications (18,23,26 and 38 GHz)
|
|
Technical Specifications (18,23,26 and 38 GHz) Pinnacle Digital Microwave Radios Operating at 13, 15, 18, 23, 26 & 38 GHz with Capacities of 155 Mbit/s OC-3/STM1 and Ethernet 100BaseT Pinnacle radios are specifically designed for high capacity synchronous and IP based applications including first and last mile network access, Sonet/SDH ring closure, and cellular base station backhaul. Pinnacle radios are meeting the growing demand for more bandwidth while maintaining high spectrum efficiency. Pinnacle Pinnacle’s versatile design allows low-cost transmission of high-capacity data through narrow or congested spectrum. This spectral efficiency is complimented by a physical architecture that promotes rapid and cost-effective installations. Using multiple plug-in modules, the indoor unit (IDU) provides various customer signal interface(s) as well as access to the SNMP and local management ports for on-site commissioning and maintenance. The outdoor unit (ODU) consists of an RF unit directly integrated with a low-profile antenna - all connected to the IDU through a single coaxial cable. For critical paths, Pinnacle can also be configured for redundant hardware protection (1+1) using either a single or dual antenna design. Versatile - Plug-In data interface modules are field interchangeable and allow simple access to all standard interfaces
- Transport for ATM and SONET/SDH based systems
- 100 BaseT Interface is ideal for LAN, WAN & ISP
- Last-mile spur access
- Cell based network back haul for GSM, PCS, Cellular, 3G
Easy To Install & Operate - Typical install time of less than 3 hours
- Integrated ODU/Antenna assembly
- Up to 1000 feet separation between ODU/IDU
- Simple graphical interface for initial set-up and maintenance
- Internal loopbacks, separate TX/RX switching, remote software downloads
- SNMP management interface
Reliable - Highly integrated MMIC, DSP, and flash technologies
- Extended MTBF
- Increased availability using redundant configuration
- Complete Digital Design
- Designed and Manufactured using ISO 9001 Standards
Technical Advantages - 128 QAM modulation allows narrow 28 MHz operation
- Offers a high gain option for wideband channels
- Advanced forward error correction (FEC)
- Automatic Transmit Power Control (ATPC)
- Dual FLASH memory for software backup
- Common IDU reduces sparing and operating costs
OUTDOOR UNIT 13, 15, 18, 23, 26 & 38 GHz Integrated RF / Antenna assembly Eliminates waveguide loss, allows polarization selection and simplifies RF replacement without affecting antenna alignment. OUTDOOR UNIT (ODU) FeaturesRF Unit Antenna AGC Monitor Port. RF Unit Latch Antenna Alignment Adjustments (Vertical and Horizontal) INDOOR UNIT 155 Mbit/s, STM-1/OC-3 Rack Mountable Either Direction INDOOR UNIT Back Panel INDOOR UNIT (IDU) Features Alarm/Status LEDs Plug-In Line Interface Module Accessory Port (Async Service Channel & HSB interconnection) Modem Port for Remote Dial-in Access Alarm Relays Network Management (10 Base-T SNMP) +24 or -48 VDC IDU to ODU Connection Single Coax Cable (RG-8 up to 300m) Local Control Craft Terminal or PC Interface (RS 232) Technical Specifications¹² System ParametersFrequency Bands: 13-38 GHz | Frequency Stability: ±2 ppm | Residual BER: <10 -13 | Transmitter Type: Digital modulator, up-converter | Power Control (ATPC): 0 to 25 dB | Receiver Type: Down converter, coherent demodulation |
Standards ComplianceSystem: FCC Part 101, ETSI EN 301 751 | Antenna: FCC Part 101 Category A or ETSI high-performance, BABT 211 ZV Class 2 | EMC: FCC Part 15 Class B, ETSI ETS 300 385, EN 301 489 | Payload/Interface: SONET applicable standards, ITU-T G.703, G.707, G.783, G.823, G.826, G.957, G.958 |
PayloadCapacity: 155.52 Mbit/s | Type: Clear channel or SONET/SDH regenerator section | Electrical Interface: CMI, BNC connectors | Optical Interface: Single or multi-mode Intra-office, short or long haul SC, ST or FC connectors | Service Channels: 19.2 Kbits asynchronous; RS-232 2 x 64 Kbits synchronous; G.703 | Wayside Channel: T1 or E1; G.703 | Ethernet User Interface: 100BaseT 100BaseT + 2T1/2E1100BaseT + 2T1/2E1 + DS3/E3 |
Frequency Dependent ParametersGeneral | 13 GHz | 15 GHz | 18 GHz | 23 GHz | 26 GHz | 38 GHz | Frequency Range | 12.75- 13.25 GHz | 14.4- 15.35 GHz | 17.7-19.7 GHz | 21.2-23.6 GHz | 24.5-26.5 GHz | 37.0-40.0 GHz | T/R Spacing | 266 MHz | 420, 490, 728 MHz | 1010, 1560 MHz | 1008,1200, 1232 MHz | 1008 MHz | 700, 1260 MHz | ETSI Specifications | EN 300 234 Class 5B | EN 300 234 Class 5B | EN 300 430 Class 5A | EN 300 198 Class 5A | EN 300 431 Class 5A | EN 300 197 Class 5A |
Standard BandwidthOutput Power | - | - | 18.0 dBm | 17.0 dBm | 17.0 dBm | 17.0 dBm | Channel Bandwidth | - | - | 40 or 55 MHz | 50 or 56 MHz | 56 MHz | 50 or 56 MHz | Modulation | - | - | 32 or 16 QAM | 16 QAM | 16 QAM | 16 QAM | Threshold @ 10 -6 BER | - | - | -71 or -73 dBm | -71 dBm | -71 dBm | -70 dBm | FCC Emission Designator | - | - | 40M0F7W | 50M0F7W | - | 50M0F7W |
Narrow BandwidthOutput Power | 18.0 dBm | 19.0 dBm | 15.5 dBm | 14.5 dBm | 14.5 dBm | 14.5 dBm | Channel Bandwidth | 28 MHz | 28 MHz | 27.5 MHz | 28 MHz | 28 MHz | 28 MHz | Modulation | 128 QAM | 128 QAM | 128 QAM | 128 or 256 QAM | 128 QAM | 128 or 256 QAM | Threshold @ 10 -6 BER | -69 dBm | -69 dBm | -69 dBm | -68 dBm | -68 dBm | -67 dBm | FCC Emission Designator | - | - | - | 25M0F7W | - | 25M0F7W |
General ParametersAntennaType: Parabolic reflector; integrated or external | Diameter: 1' (30 cm), 1.5' (45 cm), 2' (60 cm), 3' (90 cm), 4' (120 cm), 6' (180 cm) | Wind Loading: Operational: 100 mph (160 km/h), Survival: 125 mph (220 km/h) | Polarization: Linear (vertical or horizontal) | Adjustment Angle: ±35° elevation, ±15° azimuth |
PowerStandard Input: -36 VDC to -60 VDC | Optional Input²: 24 VDC ± 20% | Power Consumption: 115 watts (non-protected); 240 watts (protected) |
EnvironmentalTemperature: Operational Range: ODU: -50°C to +55°C Full Performance: ODU: -33°C to +55°C / IDU: -5°C to +45°C | Relative Humidity: ODU: 100%, IDU: up to 95% non-condensing | Altitude: 15,000 feet (4,500 m) |
MechanicalIDU Dimensions: 1 RU (4 cm) x 19" (44.5 cm) x 12" (30.5 cm) (h x w x d) | IDU Weight: 4.7 lbs. (2.14 kg) | ODU Dimensions: 38 GHz: 13" x 13" x 12" (33 x 33 x 30.5 cm) (h x w x d) 13/15/18/23/26 GHz: 11.8" x 9" x 6.3" (30 x 23 x 16 cm) (h x w x d) | ODU Weight: 15.4 lbs. (7 kg) includes RF assembly only | IDU to ODU Connection: 1 coaxial cable up to 1000' (300 m), Belden 9913 (RG-8) or equivalent, 2 'N' type male connectors |
Network ManagementType: Integral SNMP agent, Craft Terminal Interface (CTI), GUI interface | Physical Interface: PPP over RS-232 modem port (up to 56 Kbit/s), 10 BaseT Ethernet port, VT100 craft terminal port (9.6 Kbit/s) | User Interface: SNMP, CTI via Telnet, CTI via direct serial interface, GUI interface | Security: 3-level password protection, Challenge Protocol (CHAP) security | Remote Software Updates: Flash download via TFTP over Ethernet or dial-up PPP | NMS Compatibility³: OpenViewä, NetViewä or any SNMP-based NMS | NM IP Rating: IP addresses for radios and third-party equipment accessible over multiple cascaded links |
Protected Branching Loss | Primary | Standby | Transmit | 1.5 dB | 6.5 dB | Receive | 1.5 dB | 6.5 dB |
Footnotes 1) All specifications are subject to change without notice. 2) Non-protected specifications. 3) OpenView and NetView are registered trademarks of Hewlett Packard Corporation and IBM Corporation.
|
|
|
Toll Free (888) 224-6814 | Fax (603) 878-0530 | E-mail Copyright © 1997 - 2024 AIRLINX Communications, Inc. Powered by SpokenSkills
|
|
|